Related Experiment Video
Updated: Mar 16, 2026

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Prospective observational study on central line-associated bloodstream infections and central venous catheter
Parul A Patel1, Susan Boehm1, Ying Zhou1
1NorthShore University Health System, Evanston, IL.
Background:
Major complications of central venous catheter (CVC) use include bloodstream infection and occlusion. We performed a prospective, observational study to determine the rate of central line-associated bloodstream infection (CLABSI) and CVC occlusion using a negative displacement connector with an alcohol disinfecting cap.
Methods:
Patients were followed from the time of CVC insertion through 2 days after removal, at the time of hospital discharge if there was no documentation of removal, or 90 days after the insertion of the CVC if it was not removed. CLABSI was defined using National Healthcare Safety Network criteria. Data for evidence of lumen occlusions were extracted from the electronic health record. Direct observations were performed to assess adherence to hospital policy regarding CVC insertion practice.
Results:
A total of 2,512 catheters from 2,264 patients were enrolled for this study. There were 21 CLABSIs (0.84%; 95% confidence interval [CI], 0.48%-1.19%; 0.62 per 1,000 line days) and 378 occlusions (15.05%; 95% CI, 13.65%-16.45%; 11.23 per 1,000 line days). Eighty-five direct observations demonstrated insertion protocol adherence in 881 of 925 (95.24%; 95% CI, 93.87%-96.61%) measured criteria.
Conclusions:
Lines placed following a standardized protocol using a negative displacement connector with an alcohol cap have low rates of infection compared with historically published findings. We also established that the occlusion rate is >15-fold the CLABSI rate.
More Related Videos
03:24Author Spotlight: Enhancing Candida albicans Detection in Catheter Infections Using Fluorescent Protein Tagging
Published on: March 22, 2024
05:51Computed Tomography (CT) Guided Implantation of a Totally Implantable Venous Access Port (TIVAP) through Subclavian Vein
Published on: January 13, 2026
Related Concept Videos
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.
Endocarditis IV: Nursing Management
Hand hygiene
Hand washing...