The Aquamantys(®) system improves haemostasis and pneumostasis in open decortication for thoracic empyema
Edward J Caruana1, Jakub Kadlec2, Swetha Iyer1
1Papworth Hospital, Cambridge, UK ;
Background:
Decortication for thoracic empyema is associated with significant blood loss and prolonged postoperative air leak. We sought to assess the potential application of an irrigated-tip radiofrequency (RF) sealing device, in an attempt to reduce this morbidity.
Methods:
Data for all patients undergoing open decortication (OD) for stage II thoracic empyema, using either conventional approach or facilitated by use of the Aquamantys(®) device, at a single thoracic surgical unit between April 2010 and July 2014, were retrospectively analysed. Unpaired t-test and Fisher's exact test were used for statistical analysis.
Results:
Thirty-three patients, aged 54±15 years (mean ± SD), and with a Charlson comorbidity index of 2.5±1.9 were included. Preoperative and intraoperative characteristics, including surgical time, were similar in the conventional and Aquamantys(®) groups. Patients in the Aquamantys group were less likely to require red cell transfusion (9/22 vs. 10/11 patients, P=0.024) and received lower volume transfusions [0.0 (2.0) vs. 3.0 (1.6) units (median, IQR), P<0.0001]; chest drain duration was shorter [3.0 (1.0) vs. 6.5 (6.8) days, P=0.006], as was length of postoperative hospital stay [6.0 (8.7) vs. 10.0 (4.6) days, P=0.031]. There was no demonstrable difference in mortality.
Conclusions:
Our data indicates that the use of irrigated tip RF ablation is safe and effective in improving pneumostasis and haemostasis in decortication for thoracic empyema; and that this translates to morbidity and logistical benefit.
More Related Videos
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required