Related Experiment Video
Updated: Mar 16, 2026

Establishment of a Simple and Effective Rat Model for Intraoperative Parathyroid Gland Imaging
Published on: August 17, 2022
Shear wave elastography and parathyroid adenoma: A new tool for diagnosing parathyroid adenomas
Ghobad Azizi1, Kelé Piper2, James M Keller3
1Wilmington Endocrinology, 1717 Shipyard Boulevard, Wilmington, NC 28403, United States.
Objectives:
This study prospectively determines the shear wave elastography characteristics of parathyroid adenomas using virtual touch imaging quantification, a non-invasive ultrasound based shear wave elastography method.
Methods:
This prospective study examined 57 consecutive patients with biochemically proven primary hyperparathyroidism and solitary parathyroid adenoma identified by ultrasound and confirmed by at least one of the following: surgical resection, positive Technetium-99m Sestamibi Scintigraphy (MIBI) scan, or fine needle aspiration biopsy with positive PTH washout (performed only in MIBI negative patients). Vascularity and shear wave elastography were performed for all patients. Parathyroid adenoma stiffness was measured as shear wave velocity in meters per second.
Results:
The median (range) pre-surgical value for PTH and calcium were 58pg/mL (19, 427) and 10.8mg/dL (9.5, 12.1), respectively. 37 patients had positive MIBI scan. 20 patients had negative MIBI scan but diagnosis was confirmed with positive PTH washout. 42 patients underwent parathyroidectomy, and an adenoma was confirmed in all. The median (range) shear wave velocity for all parathyroid adenomas enrolled in this study was 2.02m/s (1.53, 2.50). The median (range) shear wave velocity for thyroid tissue was 2.77m/s (1.89, 3.70). The shear wave velocity of the adenomas was independent of adenoma size, serum parathyroid hormone concentration, or plasma parathyroid hormone concentration.
Conclusions:
Tissue elasticity of parathyroid adenoma is significantly lower than thyroid tissue. B-mode features and distinct vascularity pattern are helpful tools in diagnosing parathyroid adenoma with ultrasound. Shear wave elastography may provide valuable information in diagnosing parathyroid adenoma.