Related Experiment Video
Updated: Mar 16, 2026

Intra-cardiac Side-Firing Light Catheter for Monitoring Cellular Metabolism using Transmural Absorbance Spectroscopy of Perfused Mammalian Hearts
Published on: May 12, 2019
Circulatory Failure During Noninhaled Forms of Cyanide Intoxication
Philippe Haouzi1, Nicole Tubbs, Matthew D Rannals
1*Division of Pulmonary and Critical Care Medicine, Department of Medicine, Pennsylvania State University College of Medicine, Hershey, Pennsylvania †Heart and Vascular Institute, Pennsylvania State University College of Medicine, Hershey, Pennsylvania ‡Southwest Research Institute, San Antonio, Texas.
Abstract:
Our objective was to determine how circulatory failure develops following systemic administration of potassium cyanide (KCN). We used a noninhaled modality of intoxication, wherein the change in breathing pattern would not influence the diffusion of CN into the blood, akin to the effects of ingesting toxic levels of CN. In a group of 300 to 400 g rats, CN-induced coma (CN i.p., 7 mg/kg) produced a central apnea within 2 to 3 min along with a potent and prolonged gasping pattern leading to autoresuscitation in 38% of the animals. Motor deficits and neuronal necrosis were nevertheless observed in the surviving animals. To clarify the mechanisms leading to potential autoresuscitation versus asystole, 12 urethane-anesthetized rats were then exposed to the lowest possible levels of CN exposure that would lead to breathing depression within 7 to 8 min; this dose averaged 0.375 mg/kg/min i.v. At this level of intoxication, a cardiac depression developed several minutes only after the onset of the apnea, leading to cardiac asystole as PaO2 reached value approximately 15 Torr, unless breathing was maintained by mechanical ventilation or through spontaneous gasping. Higher levels of KCN exposure in 10 animals provoked a primary cardiac depression, which led to a rapid cardiac arrest by pulseless electrical activity (PEA) despite the maintenance of PaO2 by mechanical ventilation. These effects were totally unrelated to the potassium contained in KCN. It is concluded that circulatory failure can develop as a direct consequence of CN-induced apnea but in a narrow range of exposure. In this "low" range, maintaining pulmonary gas exchange after exposure, through mechanical ventilation (or spontaneous gasping), can reverse cardiac depression and restore spontaneous breathing. At higher level of intoxication, cardiac depression is to be treated as a specific and spontaneously irreversible consequence of CN exposure, leading to a PEA.
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-IV
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...

