Related Experiment Video
Updated: Mar 16, 2026

Creation of Two Saccular Elastase-Digested Aneurysms with Different Hemodynamics in One Rabbit
Published on: April 15, 2021
Combined suture and clipping for the reconstruction of a ruptured blister-like aneurysm
Sven R Kantelhardt1, Eleftherios Archavlis2, Alf Giese2
1Department of Neurosurgery, University Medical Centre, Johannes Gutenberg-University, Langenbeckstr. 1, 55129, Mainz, Germany. sven.kantelhardt@unimedizin-mainz.de.
Abstract:
Blister-like aneurysms of the internal carotid artery (ICA) present a severe therapeutical challenge. While several reconstructive techniques are in use in case of acute rupture sacrifice of the parent vessel may be required. We present a combined technique of micro-sutures and clip application to repair the parent vessel in an intraoperatively ruptured blister-like aneurysm. Following temporary trapping of an intraoperatively ruptured 7-mm blister-like aneurysm four 8-0 nylon sutures were applied to adapt the vessel walls and support the branches of subsequently applied mini-clips. The combination of micro-sutures and mini-clips might be a valuable alternative to direct clipping or suturing in some cases with intraoperative rupture of blister-like aneurysms.

