Related Experiment Video
Updated: Sep 20, 2026

The Mouse Round-window Approach for Ototoxic Agent Delivery: A Rapid and Reliable Technique for Inducing Cochlear Cell Degeneration
Published on: November 26, 2015
Role of high-frequency audiometry in the early detection of ototoxicity. II. Clinical Aspects
W A Dreschler1, R J van der Hulst, R A Tange
1Department of Otolaryngology, Academic Medical Center, University of Amsterdam, The Netherlands.
Abstract:
As a supplement to a previous paper [Dreschler et al.: Audiology 1985; 24:387-395] high-frequency (HF) audiometry was applied to compare the ototoxic effects of two different drug administration protocols for cis-platinum (CDDP). In both subgroups, HF audiometry considerably enhanced the early detection of ototoxicity. Marked differences between treatments have been established both in the pattern of onset of the damage and in the relation between dose and damage severity. For subjects treated with platinum derivatives, the thresholds at 12 and 14 kHz prove to be especially important. The results suggest that for these subjects the measurement of only a single frequency may be considered: with a minimum of effort, most of the increased sensitivity for a complete HF audiogram can be obtained. Finally, the relation between threshold deteriorations above 8 kHz and threshold deteriorations in the conventional range of audiometric frequencies has been investigated.
Related Concept Videos
The Cochlea
Auditory Pathway
When viewed cross-sectionally, the cochlea reveals the scala vestibuli and scala tympani flanking the...