Related Experiment Video
Updated: Mar 16, 2026

A Model of Self-limited Acute Lung Injury by Unilateral Intra-bronchial Acid Instillation
Published on: August 30, 2019
Iatrogenic injuries to the trachea and main bronchi
Tomasz Gil1, Janusz Warmus1, Janusz Włodarczyk1
1Department of Thoracic Surgery, Jagiellonian University Medical College, John Paul II Hospital, Krakow, Poland.
Introduction:
Iatrogenic tracheobronchial injuries are rare.
Aim:
To analyse the mechanism of injury, symptoms and treatment of these patients.
Material And Methods:
Retrospective analysis of hospital records of all patients treated for main airway injuries between 1990 and 2012 was performed.
Results:
There were 24 patients, including 21 women and 3 men. Mean time between injury and initiation of treatment was 12 hours (range: 2-48). In 16 patients the injury occurred during tracheal intubation, in 1 during rigid bronchoscopy, in 1 during rigid oesophagoscopy, in 1 during mediastinoscopy and in 5 during open surgery. Mean length of airway tear was 3.8 cm (range: 1.5-8). In 1 patient there was an injury to the cervical trachea and in the remaining 23 in the thoracic part of the airway. The treatment included repair of the membranous part of the trachea performed via right thoracotomy in 10 patients (in 1 patient additionally coverage with a pedicled intercostal muscle flap was used), a self-expanding metallic stent in 1 patient, suture of the right main bronchus and the oesophagus in 1, left upper sleeve lobectomy in 1, right upper lobectomy in 1, implantation of a silicone Y stent in 3, mini-tracheostomy in 1, and conservative treatment in 5 patients.
Conclusions:
Intubation is the most frequent cause of iatrogenic main airway injuries. Patients with these life-threatening complications require an individualised approach and treatment in a reference centre.
More Related Videos
Related Concept Videos
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...