Presence of an arterial line improves response to simulated hypotension and pulseless electrical activity
Jonathan Lipps1, Andrew Goldberg2, Samuel DeMaria2
1Department of Anesthesiology, The Ohio State University Wexner Medical Center, 410 West 10th Avenue, Columbus, OH, 43210, USA. jonathan.lipps@osumc.edu.
Abstract:
With pulseless electrical activity (PEA) emerging as one of the leading cardiac arrest arrhythmias, the rapid response and accurate diagnosis of PEA is essential to improve survival rates. Although the use of invasive blood pressure monitoring to more quickly detect changes in blood pressure is widespread, evidence for its use is largely anecdotal and placement is not without risk. This is a prospective, multi-center, randomized controlled trial involving 58 senior anesthesiology residents undergoing a simulation of intraoperative PEA using high-fidelity simulation. Of the total 58 participants, 28 subjects were randomized to invasive blood pressure monitoring and 30 to non-invasive blood pressure monitoring in order to investigate the effects of arterial line information on the response time of ACLS-trained anesthesiology residents. Response times of subjects in the group provided with invasive blood pressure monitoring were faster to palpate pulses (6.5 s faster, p = .0470), initiate chest compressions (17 s faster, p = .004), and administer 1 mg of epinephrine (21 s faster, p = .0005. The absolute number of pharmacologic interventions was increased in the group with invasive blood pressure monitoring (p = .020). These findings suggest that noninvasive blood pressure monitoring and other readily available monitors are not as powerful as invasive blood pressure monitoring in influencing decision-making during a PEA event. As there is currently no specific blood pressure at which the patient is considered to be in PEA, future studies are necessary to clarify the correlation between the arterial line tracing and the appropriate trigger for ACLS initiation.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiopulmonary Resuscitation IV: Pharmacological Management
Pulse
The pulse serves as a clinical...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure