Related Experiment Video
Updated: Jan 24, 2026

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Do mathematical model studies settle the controversy on the origin of cardiac synchronous trans-thoracic electrical
A de Sitter1,2, R M Verdaasdonk2, T J C Faes2
1VU University, Faculty of Science, Amsterdam, The Netherlands.
Abstract:
Impedance cardiography (ICG) is a method to evaluate cardiac-stroke volume and cardiac-output by measuring the cardiac-synchronous changes in the dynamic trans-thoracic electrical impedance (ΔZ). Clinical evaluations on the accuracy of ICG showed varying results. Consequently, the classic assumption in ICG-the aorta as a main source of ΔZ-is questioned and subsequently investigated in simulation studies using mathematical models of the electrical resistivity of the human body. The aim is to review the consensus in mathematical modelling studies that investigate the origin of the ΔZ as measured in ICG. In a systematic literature search, studies were identified and surveyed with reference to characteristics, such as included organs and their resistivity and geometries, electrode positions and calculation of ΔZ, to review the consensus between mathematical modelling studies that investigate the origin of the ΔZ as measured in ICG. Thirteen papers showed considerable variation in the model's characteristics with varying or contradicting outcomes for the ΔZ 's origin. For instance, 11 studies excluded perfused muscle tissue, implying implicitly their insignificance, while 3 other studies included muscle tissue and indicated it as the most important origin of ΔZ. In conclusion, the reviewed papers show a lack of consensus with respect to both the modelled characteristics as well as the model outcomes and, as a result, these studies failed to settle the controversy on ΔZ 's origin. Recommendations have been added to improve future mathematical model studies.
Related Concept Videos
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Fundamental Mathematical Principles in Pharmacokinetics: Mathematical Expressions and Units
One significant application of mathematics in pharmacokinetics is the characterization of drug distribution through the volume of distribution...
Thoracic Aorta

