Related Experiment Videos
COMPARISON OF HYDROCORTISONE 10 MG TABLETS: TABLET HARDNESS OPTIMISED FOR ADULT USE HAS NEGATIVE CONSEQUENCES FOR
Sarina Saimbi1, Valerie Madden2, Heather Stirling2
1Pharmacy and Therapeutics, College of Medical and Dental Sciences, University of Birmingham.
Insights
Parents should crush hydrocortisone tablets into a fine powder for accurate pediatric dosing. This is crucial for newer, harder hydrocortisone Auden tablets to ensure correct 2mg doses for children.
Area of Science:
- Pharmaceutical Sciences
- Pediatric Pharmacology
Background:
- Pediatric dosing often requires manipulation of adult medications.
- Recent changes in hydrocortisone tablet manufacturing increased compression force, making them harder to manipulate.
- Parents report difficulties in preparing accurate pediatric hydrocortisone doses from these modified tablets.
Purpose of the Study:
- To evaluate the suitability of 10mg hydrocortisone tablets for manipulation for pediatric dosing.
- To compare the physical properties of older and newer hydrocortisone tablets.
- To assess the accuracy of delivering a 2mg pediatric dose from manipulated tablets.
Main Methods:
- Compared physical properties (hardness, friability) of two brands of 10mg hydrocortisone tablets (older vs. newer).
- Assessed accuracy of halving and quartering tablets using a score line.
- Evaluated 2mg dose accuracy by crushing tablets and measuring concentration via UV analysis after dispersion in water.
Main Results:
- Newer hydrocortisone Auden tablets (Brand A) were significantly harder than older tablets (Brand B).
- Brand A tablets passed friability tests, while Brand B failed.
- Crushing tablets, especially with a commercial device, improved the accuracy of the 2mg pediatric dose for both brands.
Conclusions:
- Advise parents to crush hydrocortisone tablets into a fine powder for accurate pediatric dosing in water.
- Emphasize the importance of crushing for newer, harder hydrocortisone Auden tablets due to increased manipulation difficulty.
- Crushing with a dedicated device enhances dose accuracy compared to using a spoon.
Background:
Children's medicines are not always readily available as an age appropriate product and manipulation of adult products is often required. Recently the commercial manufacturing process for 10 mg hydrocortisone tablets has changed and the compression force increased due to tablets fracturing on removal from the blister pack. However, this change led to parents of children requiring hydrocortisone reporting that the tablets were more difficult to manipulate.This study evaluated 10 mg hydrocortisone tablets for their suitability for manipulation in order to deliver an appropriate dose to children (2 mg dose). The physical properties of tablets with the old and new compression force were compared as well as the accuracy of obtaining the paediatric dose.
Methods:
The tablets compared were hydrocortisone Auden 10 mg tablets (Brand A, PL16876/002)-these are the newer, harder tablets- and hydrocortisone 10 mg tablets (Brand B, PL17507/0097). Tablet physical properties including friability (Copley FRV200) and tablet hardness (Copley TBF1000) were compared. The accuracy of split doses (halve and quarter tablets) were recorded on a Sartorius analytical balance. The accuracy of the 2 mg paediatric dosing was assessed by crushing the tablet, adding 10 mL of water and extracting 2 mL. The concentration was measured using UV analysis (Jenway Genova Plus) according to a calibration curve (wavelength=246 nm). Two devices were used to crush the tablets: a spoon onto a plate and a commercially available crushing device (Apothecary Ezy Crush Pill Crusher With Ergo Grip).
Results:
As anticipated Brand A tablets were harder (51.85 ±5.1 N) compared to Brand B (30.99±4.1 N). Brand A tablets passed the friability testing with <1% weight loss whereas Brand B failed as 5 tablets broke during testing.The accuracy of split doses using the score lines to halve and quarter the tablets showed that Brand A were generally better with smaller ranges for both halves (Range for A=41-55%; B=29-70%) and quarters (Range for A=17-35%; B=12-42%) compared to Brand B.The 2 mg dosing accuracy was better for Brand B tablets compared to A and crushing tablets using a commercial device improved the accuracy of dosing for both brands of tablets. When crushing using a spoon the mean dose obtained was 1.3 mg for Brand A and 1.7 mg for Brand B; the commercial crushing device gave values of 1.9 mg for Brand A and 2.1 mg for Brand B.
Conclusion:
Parents or carers who are required to manipulate 10 mg hydrocortisone tablets to administer a dose to children dispersed in water should be advised to crush the tablet into a fine powder where possible to improve the likelihood of administering an accurate dose. This is particularly important since the introduction of new hydrocortisone Auden tablets which are known to be harder tablets and therefore more force is required to crush these.
Acknowledgements:
Some of the experimental work within this project was conducted by Andrew Hackett and Kameron Paul-Thaper whilst at the University of Birmingham on work experience from Arden Sixth Form, Station Rd, Knowle, Solihull, West Midlands, B93 0PT.
Related Concept Videos
Drug Dosing: Infants and Children
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
Antiasthma Drugs: Inhaled Corticosteroids and Glucocorticoids
ICS work through a multifaceted mechanism of action. They suppress the inflammatory response caused by the proliferation of TH cells. They also reduce the transcription of the IL-2 gene, which is involved in the...
Drugs for Treatment of Crohn's Disease in IBD Using Glucocorticoids
Dosage Regimen: Multiple Oral Dosage
Drug Dosing: Geriatric Patients