Determination of diclofenac concentrations in human plasma using a sensitive gas chromatography mass spectrometry
Iltaf Shah1, James Barker2, Declan P Naughton2
1Department of Chemistry, College of Science, United Arab Emirates University, Al Ain, UAE.
Background:
A gas chromatography mass spectrometry (GCMS) method for the determination of diclofenac in human plasma has been developed and validated.
Results:
This method utilizes hexane which is a relatively less toxic extraction solvent compared to heptane and benzene. In addition, phosphoric acid and acetone were added to the samples as deproteination agents, which increased the recovery of diclofenac. These revised processes allow clean extraction and near-quantitative recovery of analyte (approx. 89-95 %). Separation was achieved on a BP-1 column with helium as carrier gas. The molecular ion peaks of the indolinone derivatives of diclofenac ion (m/z 277) and the internal standard, 4-hydroxydiclofenac ion (m/z 439) were monitored by a mass-selective detector using selected ion monitoring (SIM) mode. The linear range for the newly developed and highly sensitive assay was between 0.25-50 ng/mL. The detection and lower quantifiable limits were 0.125 and 0.25 ng/mL, respectively. The inter-day and intra-day coefficients of variation for high, medium and low quality control concentrations were less than 9 %. The robustness and efficacy of this sensitive GCMS method was further demonstrated by using it for a pharmacokinetic study of an oral dosage form of diclofenac, 100 mg of modified-release capsules (Rhumalgan XL), in human plasma.
Conclusions:
This method is rapid, sensitive, specific, reproducible and robust, and offers improved sensitivity over previous methods. This method has considerable potential to be used for detailed pharmacokinetics, pharmacodynamics and bioequivalence studies of diclofenac in humans.
More Related Videos
14:39Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
08:38Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...