Increased electrospray ionization intensities and expanded chromatographic possibilities for emerging contaminants
1School of Education and Environment, Division of Natural Sciences, Kristianstad University, SE-291 88 Kristianstad, Sweden.
Abstract:
In this work the habitual behaviour of low pH in environmental organic trace analysis is challenged by investigating the full potential of building a multi-component UHPLC-ESI-MS/MS method adapted to cover common emerging contaminants of many different polarities, minimizing the elements of compromise in the performance of the final analytical separation and detection. Contributes have been made by taking advantage of common commercially available technology in understanding the impact from solvent components and the ionization of analytes which can facilitate future development of robust, sensitive and precise UHPLC-MS/MS methods. All contaminants were evaluated and optimized without prejudices regarding historical residence in terms of chromatographic conditions and ESI mode; increasing multi-method's flexibility that can be implemented in routine analysis in response to new requests as well as to emerging contaminants yet to be discovered. Our data strongly supports the questioning of the assumption that equilibrium concentrations of ions in solution reflect those produced during the electrospray process. ESI responses of [M+H](+) and limits of detection were comparable, or often better at high pH compared to acidic eluents. Presence of nitrogen basic groups such as tertiary and secondary amines in a compound increased the intensity of the ESI+ signal, and was even further elevated in basic eluent. The proton affinity probably changes for many nitrogen-containing compounds during the ionization process, making the gas-phase processes very important in generation of these ions by ESI+. There were also an unexpected large number of compounds showing their highest response at pH 7 and weak ionic strength. A flow optimized, buffert free, neutral UHPLC-MS/MS method enhanced the sensitivity for the environmental important synthetic hormone ethinyl estradiol significantly.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
08:40Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Elution Process
Electrophoresis: Overview
There...
High-Performance Liquid Chromatography: Types of Detectors