Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Effect of Noise-Optimized Monoenergetic Postprocessing on Diagnostic Accuracy for Detecting Incidental Pulmonary
Jakob Weiss1, Mike Notohamiprodjo, Malte Bongers
1From the Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tübingen, Tübingen, Germany.
Objectives:
The aim of this study was to evaluate the diagnostic accuracy of virtual monoenergetic images (MEI+) at low kiloelectronvolt levels for the detection of incidental pulmonary embolism (PE) in oncological follow-up portal-venous phase dual-energy (DE-CTpv) staging.
Materials And Methods:
Twenty-six patients with incidental PE in DE-CTpv staging, which was confirmed by computed tomography pulmonary angiography (CTPA), were included in this study. In addition, 26 matched control patients who were negative for PE in both DE-CTpv and CTPA were included. All examinations were performed on a third-generation DE-CT system in single-energy (CTPA) and dual-energy mode (DE-CTpv). Subsequently, 2 series of MEI+ data sets were reconstructed at 40 and 55 keV from the DE-CTpv data and compared with CTPA and the linearly blended CTpv images. Diagnostic accuracy and diagnostic confidence were calculated and compared for MEI+ reconstructions and for CTpv images regarding the detection of PE with CTPA as standard of reference.
Results:
In 3 patients, PE was only detectable in CTPA and in the 40-kV and 55-kV MEI+ reconstructions but not in CTpv images. Diagnostic accuracy increased significantly for both MEI+ series (40 keV; area under the curve [AUC], 0.928; 95% confidence interval [CI], 0.879-0.978; 55 keV; AUC, 0.960; 95% CI, 0.922-0.998) as compared with CTpv (AUC, 0.814; 95% CI, 0.741-0.887; P ≤ 0.004). Diagnostic confidence was rated highest in CTPA (median, 5; range, 3-5) followed by 55-keV MEI+ and 40-keV MEI+ (median, 5; range, 2-5 and median, 5; range, 2-5, respectively) and was lowest for CTpv (median, 4; range, 1-5), with significant differences to CTPA and MEI+ reconstructions (P ≤ 0.001).
Conclusions:
Monoenergetic image reconstructions from DE-CT data sets at low kiloelectronvolt levels improve diagnostic accuracy for the detection of incidental PE in oncological follow-up DE-CTpv staging, with the highest subjective diagnostic confidence in MEI+ at 55 keV.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
05:56Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT