Contrast Circulation Time to Assess Right Ventricular Dysfunction in Pulmonary Embolism: A Retrospective Pilot Study
Gregor John1,2, Alexandra Platon3, Pierre-Alexandre Poletti3
1Department of Internal medicine, Hôpital neuchâtelois, Chasseral 20, 2300 La Chaux-de-Fonds, Switzerland.
Objective:
To optimize enhancement of pulmonary arteries and facilitate diagnosis of pulmonary embolism (PE), modern computed tomography angiography (CTA) contains a contrast bolus tracking system. We explored the diagnostic accuracy of the time-intensity curves given by this automated system to identify right ventricular dysfunction (RVD) in acute PE.
Methods:
114 CTAs with a diagnosis of PE were reviewed. RVD was defined as right-to-left ventricular diameter ratio of 1 or greater. Four parameters on time-intensity curves were identified. Parameters between CTAs with and those without RVD were compared with the Wilcoxon rank-sum test. The ability of the four parameters to discriminate patients with RVD was explored by compiling the area under the operating curves (AUC).
Results:
The time needed by the contrast media to reach the pulmonary artery [8 seconds (IQR: 7-9) versus 7 seconds (IQR: 6-8), p<0.01], the time needed to reach 40 Hounsfield units (HU) [11 seconds (IQR: 8.5-14) versus 9.5 seconds (IQR: 8-10.5), p<0.01], and the contrast intensity reached after 10 seconds [19 HU (IQR: 4-67) versus 53 HU (IQR: 32-80), p<0.05] were all statistically different between CTA with and CTA without RVD. Those three parameters changed gradually across severity categories of RVD (p<0.05 for trend). Their AUC to identify RVD ranged from 0.63 to 0.66. The slope of contrast intensity over time was not informative: [31 HU/s (IQR: 20-57) in CTA with, compared to 36 HU/s (IQR: 22.5-53) in CTA without RVD, p = 0.60].
Conclusion:
Several parameters of the time-intensity curve obtained by the bolus tracking system are associated with RVD assessed on CTA images. Of those, the time needed to reach a predefined threshold seems to be the easiest to obtain in any CTA without additional processing time or contrast injection. However, the performance of those parameters is globally low.
More Related Videos
10:33Assessment of Right Ventricular Structure and Function in Mouse Model of Pulmonary Artery Constriction by Transthoracic Echocardiography
Published on: February 3, 2014
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Pulmonary Embolism I: Introduction
Cardiac Catheterization II: Right Heart Catheterization
Pulmonary Embolism III: Nursing Management
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...