Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Shrinkage stress kinetics of Bulk Fill resin-based composites at tooth temperature and long time
David Kalliecharan1, William Germscheid1, Richard B Price2
1Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia B3H 4R2, Canada.
Objective:
To determine the shrinkage stress kinetics at up to 12h after light exposure and at tooth temperature during placement of selected Bulk Fill resin-based composites (RBCs).
Methods:
Five representative Bulk Fill RBCs from four companies were chosen with a wide range of viscosity and filler volume content. The shrinkage stress kinetics at T=33°C was measured continuously over a period of 12h using a modified tensometer with the ability to measure the cantilever beam deflection to better than 40nm accuracy at a sampling rate of up to 200 samples/s, and thermally stable resulting in a measurement accuracy better than 0.05MPa at 12h. The tensometer compliance was 0.105μm/N. A custom made heater was used to control the RBC sample temperature at T=33°C with a temperature gradient across the sample of less than 1°C. The samples were irradiated for 20s with irradiance of 1.1W/cm2 and total energy density of 22J/cm2. Three samples (n=3) were used for each RBCs.
Results:
The shrinkage stress at 12h for the five Bulk Fill RBCs ranged from 2.21 to 3.05MPa, maximum stress rate ((dS/dt)M) varied from 0.18 to 0.41MPa/s, time at which the maximum stress rate occurred (tMax) were between 1.42 to 3.24s and effective gel time (tgel) varied from 50 to 770ms. Correlations were observed between (dS/dt)M and tMax (r=-0.946), tMax and filler volume fraction (r=-0.999), and between the shrinkage stress at 12h and tgel (r=0.994). However, no correlation was observed between the stress at 12h and filler volume fraction.
Significance:
The shrinkage stress for four of the five Bulk Fill RBCs were not significantly different (p<0.05) at 6h and beyond after photo-curing and that fully developed stress induced by photo-cured RBCs may only be reached at times longer than 12h.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Related Concept Videos
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction...
Thermal Stress
Plastic Behavior
Residual Stresses