Related Experiment Video
Updated: Mar 16, 2026

Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
Active Clearance of Chest Tubes Reduces Re-Exploration for Bleeding After Ventricular Assist Device Implantation
Simon Maltais1, Mary E Davis, Nicholas A Haglund
1From the *Department of Cardiac Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota; †Department of Surgery, Duke University Medical Center, Durham, North Carolina; ‡Department of Cardiac Surgery, §Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee; ¶Montreal Heart Institute, Montreal, Canada; ‖Department of Cardiology, Mayo Clinic College of Medicine, Rochester, Minnesota; and #Department of Thoracic Surgery, St. Charles Medical Center, Bend, Oregon.
Abstract:
Chest tubes are utilized to evacuate shed blood after left ventricular assist device (LVAD) implantation, however, they can become clogged, leading to retained blood. We implemented a protocol for active tube clearance (ATC) of chest tubes to determine if this might reduce interventions for retained blood. A total of 252 patients underwent LVAD implantation. Seventy-seven patients had conventional chest tube drainage (group 1), whereas 175 patients had ATC (group 2). A univariate and multivariate analysis adjusting for the use of conventional sternotomy (CS) and minimally invasive left thoracotomy (MILT) was performed. Univariate analysis revealed a 65% reduction in re-exploration (43-15%, p < 0.001), and an 82% reduction in delayed sternal closure (DSC; 34-6%, p <0.001). In a sub-analysis of CS only, there continued to be statistically significant 53% reduction in re-exploration (45% vs. 21%, p = 0.0011), and a 77% reduction in DSC (35% vs. 8%, p < 0.001) in group 2. Using a logistic regression model adjusting for CS versus MILT, there was a significant reduction in re-exploration (odds ratio [OR] = 0.44 [confidence interval {CI} = 0.23-0.85], p = 0.014) and DSC (OR = 0.20 [CI = 0.08-0.46], p <0.001) in group 2. Actively maintaining chest tube patency after LVAD implantation significantly reduces re-exploration and DSC.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Aneurysm IV: Nursing Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...

