Related Experiment Video
Updated: Mar 15, 2026

Rapid Homogeneous Detection of Biological Assays Using Magnetic Modulation Biosensing System
Published on: June 13, 2010
Detection of modiolar proximity through bipolar impedance measurements
Jason Pile1, Alex D Sweeney2, Shaun Kumar3
1Department of Engineering, Vanderbilt University, Nashville, Tennessee, U.S.A.
Objectives:
To test the hypothesis that bipolar electrical impedance measurements in perimodiolar cochlear implants (CIs) may be used to differentiate between perimodiolar insertion technique favoring proximity to the modiolus or lateral wall.
Study Design And Methods:
Bipolar impedances are a measure of electrical resistance between pairs of electrode contacts in a CI. Stimulation is through biphasic pulses at fixed frequency. Impedance measurements were made in real time through sequential sampling of electrode pairs. Perimodiolar electrodes were inserted in temporal bones using one of two techniques: 1) In the standard insertion technique (SIT), the electrode array slides along the lateral wall during insertion. 2) In the Advance Off Stylet (Cochlear Ltd. Sydney) technique (AOS), the electrode maintains modiolar contact throughout the insertion process. A set of 22 insertions were performed in temporal bone specimens using perimodiolar electrode arrays with both AOS and SIT. Buffered saline was used as a substitute for natural perilymph based on similar electrical conductivity properties. Impedance with and without stylet removal were recorded with a 30-second sampling window at final insertion depth.
Results:
There is a significant difference in bipolar impedance measures between AOS and SIT, with impedances rising in measurements with stylet removal. Evaluation was based on two-sided analysis of variance considering technique and electrode with P < 0.025.
Conclusion:
Bipolar electrical impedance can be used to detect relative motion toward the modiolus inside the cochlea. This detection method has the potential to optimize intraoperative placement of perimodiolar electrode arrays during implantation. We anticipate that this will result in lower excitation thresholds and improved hearing outcome.
Level Of Evidence:
NA. Laryngoscope, 127:1413-1419, 2017.
Related Concept Videos
Impedance Combination
Impedances and Admittance
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
Bipolar Junction Transistor
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...

