Related Experiment Video
Updated: Mar 15, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Computed Tomographic Angiography of the Abdomen and Pelvis in Azotemic Patients Utilizing 80-kV(p) Technique and
David Knipp1, Barton F Lane, Jason W Mitchell
1From the *Department of Radiology, Massachusetts General Hospital, Boston, MA; and †Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD.
Objective:
To evaluate image quality (IQ) of a reduced contrast volume, low kilovolt (peak) [kV(p)] abdominopelvic computed tomographic angiography (AP-CTA) protocol compared to a standard 120-kV(p) AP-CTA protocol.
Methods:
A retrospective image analysis was performed on 103 patients with end-stage renal disease who underwent AP-CTA. Forty-nine patients were scanned at 80 kV(p) with a mean of 48 mL of contrast, and 54 patients were scanned at 120 kV(p) with a mean of 98 mL of contrast. Objective comparison of arterial attenuation, noise, and contrast-to-noise ratio was obtained, in addition to radiation dose. Subjective assessment of IQ, enhancement intensity, and image noise (IN) was scored on a 3-point scale.
Results:
The 6-level aggregate contrast-to-noise ratio for the 80-kV(p) group was 11.8 ± 7.0, compared to 12.4 ± 4.6 in the 120-kV(p) group (P = 0.210). Radiation exposure was significantly lower in the 80-kV(p) group versus the 120-kV(p) group, as measured by average CT dose index (mGy) of 9.0 ± 3.1 and 15.8 ± 5.8 (P < 0.0001), respectively; and average dose length product (mGy × cm) of 490.0 ± 214.1 and 863.1 ± 344.4 (P < 0.0001), respectively. The 120-kV(p) technique scored better for subjective IQ (P = 0.042) and IN (P = 0.004) but not for enhancement intensity (P = 0.205).
Conclusions:
A 50% reduced iodinated contrast dose coupled with 80-kV(p) technique with iterative reconstruction allows for satisfactory AP-CTA studies at a 43% mean radiation dose reduction compared to a standard protocol. Negative but potentially reversible sequelae of this drop in radiation dose include increased IN and reduced subjective IQ.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
09:23Author Spotlight: Enhancing Transplantation Research Through MicroCT Angiography in Murine Models
Published on: September 22, 2023
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...