Two-Dimensional Time-Harmonic Elastography of the Human Liver and Spleen
Heiko Tzschätzsch1, Manh Nguyen Trong2, Tobias Scheuermann1
1Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany.
Abstract:
Measurement of shear wave speed of the liver and spleen by elastography is an established diagnostic procedure for the detection of hepatic fibrosis, portal hypertension and esophageal varices. However, current elastography systems are limited by the size and penetration depth of elastographic windows. In this study, 2D time-harmonic elastography is proposed for generating full field-of-view shear wave speed maps in great depth. Two-dimensional time-harmonic elastography uses external harmonic stimulation at multiple frequencies to create compound shear wave speed maps. The method is tested in a phantom with soft and stiff inclusions and used for elastography of the liver and spleen in 13 asymptomatic volunteers. Each volunteer was scanned twice to determine the sensitivity of the method to physiologic variations: first, after 2 h of fasting, and a second time, 15 min after drinking 1 L of water. The wave speed maps of the phantom clearly identified the soft and stiff inclusions, yielding values that were consistent with those from magnetic resonance elastography. In vivo wave speed values were 1.49 ± 0.11 m/s for the liver and 2.03 ± 0.15 m/s for the spleen in a lower-frequency band centered at 40 Hz and 3.15 ± 0.30 m/s for the spleen in a higher-frequency band centered at 120 Hz. After water intake, wave speed values increased by 6% in the liver (p = 0.002) and decreased in the spleen by 4% (p = 0.021, low-frequency band) and 6% (p = 0.0002, high-frequency band), suggesting the high sensitivity of the method to altered blood flow and perfusion pressure. Two-dimensional time-harmonic elastography of the liver and spleen is a promising method for measuring tissue stiffness at different states of blood flow and perfusion in a large tissue window and at great penetration depth.
More Related Videos
07:13Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Gross Anatomy of the Liver
Located under the diaphragm, the liver is almost entirely ensconced within the rib cage, providing it with substantial protection. Except for the superior most bare area, the liver's surface is...
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...