A simple decontamination approach using hydrogen peroxide vapour for Bacillus anthracis spore inactivation
J P Wood1, M W Calfee1, M Clayton2
1National Homeland Security Research Center, United States Environmental Protection Agency, Research Triangle Park, NC, USA.
Aims:
To evaluate the use of relatively low levels of hydrogen peroxide vapour (HPV) for the inactivation of Bacillus anthracis spores within an indoor environment.
Methods And Results:
Laboratory-scale decontamination tests were conducted using bacterial spores of both B. anthracis Ames and Bacillus atrophaeus inoculated onto several types of materials. Pilot-scale tests were also conducted using a larger chamber furnished as an indoor office. Commercial off-the-shelf (COTS) humidifiers filled with aqueous solutions of 3 or 8% hydrogen peroxide (H2 O2 ) were used to generate the HPV inside the mock office. The spores were exposed to HPV for periods ranging from 8 h up to 1 week.
Conclusions:
Four- to seven-day exposures to low levels of HPV (average air concentrations of approx. 5-10 parts per million) were effective in inactivating B. anthracis spores on multiple materials. The HPV can be generated with COTS humidifiers and household H2 O2 solutions. With the exception of one test/material, B. atrophaeus spores were equally or more resistant to HPV inactivation compared to those from B. anthracis Ames.
Significance And Impact Of The Study:
This simple and effective decontamination method is another option that could be widely applied in the event of a B. anthracis spore release.
More Related Videos
11:47Evaluation of the Efficacy of Organic Peroxyacids for Eradicating Dairy Biofilms Using an Approach Combining Static and Dynamic Methods
Published on: December 9, 2022
13:47Opsono-Adherence Assay to Evaluate Functional Antibodies in Vaccine Development Against Bacillus anthracis and Other Encapsulated Pathogens
Published on: May 19, 2020
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Physical Methods for Controlling Microbial Growth: Temperature
Chemical Agents for Microbial Control
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...