Related Concept Videos

Secondary Distribution01:25

Secondary Distribution

623
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
623
Reclosers and Fuses01:26

Reclosers and Fuses

520
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
520
Control of Power Flow01:30

Control of Power Flow

734
There are several methods to control power flow in power systems:
734
Load-frequency control01:28

Load-frequency control

734
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
734
RL Circuit with Source01:14

RL Circuit with Source

2.2K
When an RL (Resistor-Inductor) circuit is connected to a DC source, the complete response of the circuit can be divided into two parts: the transient response and the steady-state response.
The transient response of the circuit is its temporary reaction to the sudden application of the DC source. This response is characterized by a current that exponentially decays to zero as time approaches infinity. During this transitional period, the inductor behaves like a short circuit, causing the source...
2.2K
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

493
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
493

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Life Stage Differences in Vision Difficulty and Receipt of a Past-Year Eye Examination Among Midlife and Older Adults: Analysis of a National Sample.

Public health reports (Washington, D.C. : 1974)·2026
Same author

Cancer Screening in Federally Qualified Health Centers by Neighborhood Social Vulnerability: A National Study.

Journal of general internal medicine·2026
Same author

Vision and Cognitive Difficulties From Midlife to Late Life: Findings From the National Health Interview Survey.

Journal of aging and health·2025
Same author

Racial disparities in posttransplant outcomes among recipients undergoing simultaneous liver-kidney transplantation.

European journal of gastroenterology & hepatology·2025
Same author

Comparative efficacy and safety of SpyGlass percutaneous transhepatic cholangioscopy versus conventional cholangioscopy in challenging biliary access: a systematic review and meta-analysis.

European journal of gastroenterology & hepatology·2025
Same author

Objectively measured environmental features and their association with cognition and dementia: A systematic review and meta-analysis.

Ageing research reviews·2024
Same journal

Erratum: Low-dimensional model for adaptive networks of spiking neurons [Phys. Rev. E 111, 014422 (2025)].

Physical review. E·2026
Same journal

Disentangling the effects of many-body forces on depletion interactions.

Physical review. E·2026
Same journal

Charge transport and mode transition in dual-energy electron beam diodes.

Physical review. E·2026
Same journal

Optimization of multisite reactions in complex compartmentalized media.

Physical review. E·2026
Same journal

Origin of geometric cohesion in nonconvex granular materials: Interplay between interdigitation and rotational constraints enhancing frictional stability.

Physical review. E·2026
Same journal

Interaction of walkers with a standing Faraday wave.

Physical review. E·2026
See all related articles

Related Experiment Video

Updated: Mar 15, 2026

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
06:04

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator

Published on: February 14, 2025

1.1K

Long-range response in ac electricity grids.

Daniel Jung1, Stefan Kettemann1

  • 1Department of Physics and Earth Sciences, Focus Area Health, Jacobs University Bremen, 28759 Bremen, Germany.

Physical Review. E
|August 31, 2016
PubMed
Summary
This summary is machine-generated.

Changes in electricity grid topology can unexpectedly cause distant overloads. This study investigates AC grids, finding power law decay in power flow changes with distance, even in real-world networks.

More Related Videos

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
04:35

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment

Published on: July 5, 2024

2.5K
A Guide to Concentration Alternating Frequency Response Analysis of Fuel Cells
11:18

A Guide to Concentration Alternating Frequency Response Analysis of Fuel Cells

Published on: December 11, 2019

7.2K

Related Experiment Videos

Last Updated: Mar 15, 2026

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
06:04

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator

Published on: February 14, 2025

1.1K
Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
04:35

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment

Published on: July 5, 2024

2.5K
A Guide to Concentration Alternating Frequency Response Analysis of Fuel Cells
11:18

A Guide to Concentration Alternating Frequency Response Analysis of Fuel Cells

Published on: December 11, 2019

7.2K

Area of Science:

  • Physics
  • Electrical Engineering
  • Complex Systems

Background:

  • Electricity grids are complex systems where local changes can have non-local effects.
  • Predicting grid robustness against topological alterations (e.g., outages, extensions) is challenging.
  • Previous studies explored DC grids; AC grid responses remained less understood.

Purpose of the Study:

  • To investigate the long-range response of AC electricity grids to topological changes.
  • To analyze how power flow changes propagate with distance in AC grids.
  • To compare findings in idealized grids with real-world network behavior.

Main Methods:

  • Solving the real part of static AC load flow equations.
  • Analyzing power flow changes as a function of distance from a topological disturbance.
  • Utilizing a regular 2D grid graph with cyclic boundary conditions for theoretical analysis.
  • Applying the analysis to the German transmission grid topology.

Main Results:

  • A power law decay in power flow change with distance was observed in idealized AC grids.
  • The power exponent demonstrated an increase and subsequent saturation for larger system sizes.
  • Long-range responses to topological changes were also identified in the real-world German transmission grid.

Conclusions:

  • AC grid topology changes can induce significant, long-range power flow responses.
  • The observed power law decay provides a quantitative understanding of disturbance propagation.
  • Real-world grids exhibit complex, long-range dynamics similar to theoretical models, highlighting the need for robust grid management strategies.