Long contoured locking plate fixation of traumatic proximal humeral fractures with distal extension
Joby J George Malal1, Alistair I W Mayne1, Faten Arouri1
1Department of Trauma and Orthopaedics, Royal Liverpool & Broadgreen University Hospitals, Liverpool, UK.
Background:
There is a paucity of data available with respect to outcome on long contoured locking plate fixation for proximal humerus fractures with distal fracture extension.
Methods:
Thirty-four patients with traumatic proximal humerus fractures with distal extension underwent fixation with long contoured locking plates. Twenty-five patients (74%) were included in the study: one patient died, two patients had unrelated illnesses resulting in them being unable to complete follow-up assessment and six were lost to follow-up. Patients' case notes and radiographs were retrospectively reviewed, and patients were contacted to assess functional outcome using the Visual Analogue Scale (VAS) for pain, Disabilities of the Arm, Shoulder and Hand (DASH) score, Oxford Shoulder Score (OSS) and Stanmore Percentage of Normal Shoulder Assessment (SPONSA).
Results:
Mean follow-up was 27 months (range 11 months to 60 months). Mean pain at final follow-up was 3.6 [95% confidence interval (CI) = 2.5 to 4.8] with only four patients having residual pain greater than 5 on the VAS scale. Mean DASH score was 41.2 (95% CI = 32.0 to 50.4), mean OSS was 29.1 (95% CI = 24.3 to 33.9) and mean SPONSA was 63.9% (95% CI = 50.8 to 77.2). There was one wound infection. Three patients had non-unions that required bone grafting and revision internal fixation.
Conclusions:
We feel long contoured locking plates represent a useful treatment option for complex proximal humerus fractures.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Humerus