Partial tendon tear as unusual cause of trigger finger: a case report
Cosma Calderaro1, Matteo Guzzini1, Marco Pagnottelli1
1Orthopaedic and Traumatology Unit, S. Andrea Hospital, Faculty of Medicine and Psychology, 'Sapienza' University of Rome , Rome , Italy.
Case Reports in Plastic Surgery & Hand Surgery
|September 2, 2016
Abstract:
We report a case of post-traumatic trigger finger due to a partial longitudinal tear of the flexor digitorum superficialis. The suspect came from the clinical history and the young age of the patient. It was successfully treated with tendon flap suture and pulley A1 release.