State of the Art Cranial Ultrasound Imaging in Neonates
Published on: February 2, 2015
Ultrasound as a primary screening tool for detecting low birthweight newborns: A meta-analysis
1Department of Medicine and Public Health, Nagoya Medical Science Research Institute, Nagoya, Japan.
Background:
As low birthweight (i.e., birthweight < 2500 g) is a major determinant of neonatal mortality and morbidity, the pre-delivery detection of low birthweight is clinically advantageous. This study was performed to determine whether ultrasound is suitable for use in primary screening to detect low birthweight newborns.
Methods:
The primary outcomes included sensitivity, specificity, and positive and negative likelihood ratios of ultrasound detection of low birthweight newborns. Ten databases, including PubMed, were searched. All English language studies that provided true- and false-positive and true- and false-negative results regarding the pre-delivery ultrasound detection of low birthweight newborns were eligible for inclusion in the analysis. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies. Bivariate diagnostic meta-analysis was performed and hierarchical summary receiver operating characteristic curves were constructed.
Results:
Studies of relatively good quality were included in the analysis to evaluate crown-rump length (n = 12); femur length (n = 5); formulas of Campbell, Hadlock, and Shepard (n = 9); and uterine artery blood flow (n = 7). All showed low sensitivity (=0.24-0.58) regardless of specificity (=0.60-0.96). The formulas of Campbell, Hadlock, and Shepard were usable for a confirmation strategy only (positive and negative likelihood ratios = 14.8 and 0.44, respectively), but crown-rump or femur length, and uterine artery blood flow were not usable for an exclusion or confirmation strategy (positive and negative likelihood ratios = 1.4-2.8 and 0.71-0.85, respectively).
Conclusions:
Primary screening does not have to confirm low birthweight, but should almost always categorize low birthweight as a positive result and exclude normal birthweight. Therefore, ultrasound is not suitable as a primary screening tool to detect low birthweight newborns.
More Related Videos
06:43High Frequency Ultrasound for the Analysis of Fetal and Placental Development In Vivo
Published on: November 8, 2018
06:15Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies II: Ultrasonography