Related Experiment Video For Computed tomography (CT)
Updated: Mar 15, 2026

Author Spotlight: A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules
Published on: May 19, 2023
A novel approach to CAD system for the detection of lung nodules in CT images
Muzzamil Javaid1, Moazzam Javid2, Muhammad Zia Ur Rehman1
1Department of Biomedical Engineering and Sciences, School of Mechanical and Manufacturing Engineering, National University of Sciences and Technology (NUST), Islamabad, Pakistan.
Abstract:
Detection of pulmonary nodule plays a significant role in the diagnosis of lung cancer in early stage that improves the chances of survival of an individual. In this paper, a computer aided nodule detection method is proposed for the segmentation and detection of challenging nodules like juxtavascular and juxtapleural nodules. Lungs are segmented from computed tomography (CT) images using intensity thresholding; brief analysis of CT image histogram is done to select a suitable threshold value for better segmentation results. Simple morphological closing is used to include juxtapleural nodules in segmented lung regions. K-means clustering is applied for the initial detection and segmentation of potential nodules; shape specific morphological opening is implemented to refine segmentation outcomes. These segmented potential nodules are then divided into six groups on the basis of their thickness and percentage connectivity with lung walls. Grouping not only helped in improving system's efficiency but also reduced computational time, otherwise consumed in calculating and analyzing unnecessary features for all nodules. Different sets of 2D and 3D features are extracted from nodules in each group to eliminate false positives. Small size nodules are differentiated from false positives (FPs) on the basis of their salient features; sensitivity of the system for small nodules is 83.33%. SVM classifier is used for the classification of large nodules, for which the sensitivity of the proposed system is 93.8% applying 10-fold cross-validation. Receiver Operating Characteristic (ROC) curve is used for the analysis of CAD system. Overall sensitivity of the system is 91.65% with 3.19 FPs per case, and accuracy is 96.22%. The system took 3.8 seconds to analyze each image.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography

