Deni Hardiansyah1, Wei Guo2, Peter Kletting3
1Medical Radiation Physics/Radiation Protection, Medical Faculty Mannheim, Universitätsmedizin Mannheim, Heidelberg University, Mannheim 68167, Germany and Department of Radiation Oncology, Medical Faculty Mannheim, Universitätsmedizin Mannheim, Heidelberg University, Mannheim 68167, Germany.
Purpose:
The aim of this study was to investigate the accuracy of PET-based treatment planning for predicting the time-integrated activity coefficients (TIACs).
Methods:
The parameters of a physiologically based pharmacokinetic (PBPK) model were fitted to the biokinetic data of 15 patients to derive assumed true parameters and were used to construct true mathematical patient phantoms (MPPs). Biokinetics of 150 MBq (68)Ga-DOTATATE-PET was simulated with different noise levels [fractional standard deviation (FSD) 10%, 1%, 0.1%, and 0.01%], and seven combinations of measurements at 30 min, 1 h, and 4 h p.i. PBPK model parameters were fitted to the simulated noisy PET data using population-based Bayesian parameters to construct predicted MPPs. Therapy simulations were performed as 30 min infusion of (90)Y-DOTATATE of 3.3 GBq in both true and predicted MPPs. Prediction accuracy was then calculated as relative variability vorgan between TIACs from both MPPs.
Results:
Large variability values of one time-point protocols [e.g., FSD = 1%, 240 min p.i., vkidneys = (9 ± 6)%, and vtumor = (27 ± 26)%] show inaccurate prediction. Accurate TIAC prediction of the kidneys was obtained for the case of two measurements (1 and 4 h p.i.), e.g., FSD = 1%, vkidneys = (7 ± 3)%, and vtumor = (22 ± 10)%, or three measurements, e.g., FSD = 1%, vkidneys = (7 ± 3)%, and vtumor = (22 ± 9)%.
Conclusions:
(68)Ga-DOTATATE-PET measurements could possibly be used to predict the TIACs of (90)Y-DOTATATE when using a PBPK model and population-based Bayesian parameters. The two time-point measurement at 1 and 4 h p.i. with a noise up to FSD = 1% allows an accurate prediction of the TIACs in kidneys.
More Related Videos
Related Concept Videos
Noncompartmental Analysis: Mean Residence Time
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Radioactive Decay and Radiometric Dating
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Dosage Regimens: Partial Pharmacokinetic Parameters