Does laminar flow ventilation reduce the rate of infection? an observational study of trauma in England
E M Pinder1, A Bottle2, P Aylin2
1Colchester General Hospital, Turner Road, Colchester CO4 5JL, UK.
Aims:
To determine whether there is any difference in infection rate at 90 days between trauma operations performed in laminar flow and plenum ventilation, and whether infection risk is altered following the installation of laminar flow (LF).
Patients And Methods:
We assessed the impact of plenum ventilation (PV) and LF on the rate of infection for patients undergoing orthopaedic trauma operations. All NHS hospitals in England with a trauma theatre(s) were contacted to identify the ventilation system which was used between April 2008 and March 2013 in the following categories: always LF, never LF, installed LF during study period (subdivided: before, during and after installation) and unknown. For each operation, age, gender, comorbidity, socio-economic deprivation, number of previous trauma operations and surgical site infection within 90 days (SSI90) were extracted from England's national hospital administrative Hospital Episode Statistics database. Crude and adjusted odds ratios (OR) were used to compare ventilation groups using hierarchical logistic regression. Subanalysis was performed for hip hemiarthroplasties.
Results:
A total of 803 065 trauma operations were performed during this time; 19 hospitals installed LF, 124 already had LF, 13 had PV and the type of ventilation was unknown in 28. Patient characteristics were similar between the groups. The rate of SSI90 was similar for always LF and PV (2.7% and 2.4%). For hemiarthroplasties of the hip, the rates of SSI90 were significantly higher for LF compared with PV (3.8% and 2.6%, OR 1.45, p = 0·001). Hospitals installing LF did not see any statistically significant change in the rate of SSI90.
Conclusion:
The results of this observational study imply that infection rate is similar when orthopaedic trauma surgery is performed in LF and PV, and is unchanged by installing LF in a previously PV theatre. Cite this article: Bone Joint J 2016;98-B:1262-9.
More Related Videos
09:31Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....