Related Experiment Video
Updated: Mar 15, 2026

Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024
Retentive Properties of O-Ring and Locator Attachments for Implant-Retained Maxillary Overdentures: An In Vitro Study
Moustafa Abdou ELsyad1, Abdelsalam Amohamed Elhaddad1, Ahmed Samir Khirallah1
1Department of Removable Prosthodontics, Faculty of Dentistry, University of Mansoura, Eldakahlia, Egypt.
Purpose:
To evaluate and compare retentive properties of O-ring and Locator attachments for implant-retained maxillary overdentures.
Materials And Methods:
Four implant analogs were inserted in canine and second premolar areas of an acrylic edentulous maxillary model. A metal-reinforced experimental acrylic overdenture was constructed and connected to the analogs using either O-ring (group I) or Locator (group II) attachments. Locators were divided into 3 subgroups according the degree of retention of the patrix nylon insert: Locator extra-light retention (group IIa), Locator light retention (group IIb), and Locator medium retention (group IIc). Vertical and oblique (lateral, anterior, and posterior) dislodging forces were measured at the beginning of the study (initial retention) and after 540 cycles of denture insertion and removal (final retention).
Results:
For vertical, lateral, and anterior dislodging, group IIc recorded the highest initial and final retention, and group I recorded the lowest retention. For posterior dislodging, group I recorded the highest retention, and group IIa recorded the lowest retention. For group II, vertical dislodging recorded the highest initial and final retention, and lateral dislodging recorded the lowest retention. For group I, posterior dislodging recorded the highest initial and final retention, and lateral dislodging recorded the lowest retention. For all dislodging forces (except posterior dislodging), the highest retention loss was recorded in group I, and the lowest retention loss was recorded in group IIa.
Conclusion:
Locator medium attachment was associated with favorable retention during axial (vertical) and nonaxial (anterior and lateral) dislodging compared to other types of Locator inserts and O-ring attachments after a simulated 6-month period of overdenture use.