Related Experiment Video
Updated: Mar 15, 2026

Comprehensive Endovascular and Open Surgical Management of Cerebral Arteriovenous Malformations
Published on: October 20, 2017
Vasa previa evaluated by noncontrast time-of-flight magnetic resonance angiography
Naoyuki Iwahashi1, Nami Ota1, Michihisa Shiro1
1Department of Obstetrics and Gynecology, Wakayama Medical University, Wakayama, Japan.
Objective:
Vasa previa is a rare complication, and rupture of vasa previa during pregnancy may lead to significant perinatal mortality. Here, we report a case of vasa previa evaluated prenatally using noncontrast time-of-flight magnetic resonance angiography (TOF MRA).
Case Report:
A 22-year-old primiparous woman was referred to our hospital due to suspicion of vasa previa. Transvaginal ultrasonography showed two vessels running over the internal os. To obtain further information, magnetic resonance imaging (MRI) and TOF MRA were performed. Caesarean section was carried out, and macroscopic findings of the vascular distribution on the fetal membrane were consistent with those identified by TOF MRA.
Conclusion:
TOF MRA in addition to MRI may be an option for prenatal identification of the precise three-dimensional vascular distribution in patients with vasa previa.
More Related Videos
10:16Retrograde Perfusion and Filling of Mouse Coronary Vasculature as Preparation for Micro Computed Tomography Imaging
Published on: February 10, 2012
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System V: CT