Calibration and evaluation of routine methods by serum certified reference material for aldosterone measurement in
Tetsuo Nishikawa1, Masao Omura, Migaku Kawaguchi
1Endocrinology and Diabetes Center, Yokohama Rosai Hospital, Yokohama, Japan.
Abstract:
We attempted to study the standardization of aldosterone measurement in blood. The serum certified reference material (serum CRM) was established by spiking healthy human serum with pure aldosterone. ID-LC/MS/MS as a reference measurement procedure was performed by using the serum CRM. LC-MS/MS as a comparison method (CM) was routinely used for clinical samples, and the values with and without calibration by the serum CRM were compared. The serum CRM demonstrated similar reactivity with peripheral blood plasma as clinical samples in routine methods (RM) of RIA, ELISA, and CLEIA. In comparison between RM and CM, the results in regression analysis indicated that the range of the correlation coefficient (r) was 0.913 - 0.991, the range of y intercept was 0.9 - 67.3 pg/mL and the range of slope was 0.869 - 1.174. The values by RM in 100 - 150 pg/mL for the diagnostic level, had a significant calibration effect, and the relative difference between calibrated value in RM and result by CM was within ±20%. Furthermore, the calibrated value using the serum CRM was 10,187 pg/mL, which corresponds to measured value of 14,000 pg/mL using RIA for the adrenal venous sampling. Measured values between plasma and serum as a sample for the aldosterone measurement from clinical samples showed no significant differences. In conclusion, we succeeded to prepare the certified reference material of aldosterone for RM. Then, we can accurately calculate corrected values by using our equation for four RMs of determination of aldosterone.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Regulation of Sodium and Potassium
Sodium Regulation
Sodium ions make up approximately 90% of extracellular cations, with a normal blood plasma concentration of 136–148 mEq/L. A decrease in blood volume and pressure triggers the release of renin from granular cells in the juxtaglomerular complex (JGC), primarily...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Errors occurring during blood pressure monitoring
Several factors...