Monitoring of bacterial contamination of dental unit water lines using adenosine triphosphate bioluminescence
A Watanabe1, N Tamaki2, K Yokota3
1Department of Oral Health Care and Rehabilitation, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan.
Abstract:
Bacterial contamination of dental unit waterlines (DUWLs) was evaluated using ATP bioluminescence analysis and a conventional culture method. Water samples (N=44) from DUWLs were investigated for heterotrophic bacteria by culture on R2A agar, which gave counts ranging from 1.4×103 to 2.7×105 cfu/mL. The ATP bioluminescence results for DUWL samples ranged from 6 to 1189 relative light units and could be obtained within 1min; these correlated well with the culture results (r=0.727-0.855). We conclude that the results of the ATP bioluminescence assay accurately reflect the results of conventional culture-based testing. This method is potentially useful for rapid and simple monitoring of DUWL bacterial contamination.