International validation of a dithiothreitol (DTT)-based method to resolve the daratumumab interference with blood
Claudia I Chapuy1, Maria D Aguad2, Rachel T Nicholson3
1Dana-Farber Cancer Institute at St Elizabeth's Medical Center, Boston, Massachusetts.
Background:
Daratumumab (DARA) consistently interferes with routine blood bank serologic testing by directly binding to CD38 expressed on reagent red blood cells (RBCs). Treating RBCs with dithiothreitol (DTT) eliminates the DARA interference. We conducted an international, multicenter, blinded study aimed at validating the DTT method for use by blood bank laboratories worldwide.
Study Design And Methods:
Paired plasma sample unknowns were sent to 25 participating blood bank laboratories. Sample 1 was spiked with DARA only (10 µg/mL), and Sample 2 with DARA plus a clinically significant RBC antibody (anti-D [n = 6], anti-Fya [n = 9], or anti-s [n = 10]). Sites were instructed to perform an antibody screen with and without DTT-treated RBCs and to use a DTT-treated RBC panel for antibody identification. Qualitative data about the DTT method were collected by online survey. The primary outcome was the proportion of study sites able to identify the antibody unknown in the presence of DARA.
Results:
All sites observed the DARA interference with the antibody screen. The DARA interference was seen with all testing methods (gel, tube, or solid phase). Using the DTT method, 25 of 25 sites (100%) successfully identified the antibody unknown in the presence of DARA. Feedback on the DTT method was positive, with 17 of 19 (90%) sites responding to the survey indicating that they planned to use the DTT method to test clinical samples from DARA-treated patients.
Conclusion:
The DTT method is robust and reproducible and can be implemented by transfusion services worldwide to help provide safe blood products to patients treated with DARA.
More Related Videos
10:15The Use of the Ex Vivo Chandler Loop Apparatus to Assess the Biocompatibility of Modified Polymeric Blood Conduits
Published on: August 20, 2014
10:12Author Spotlight: Quantitative Detection of DNA Protein Crosslinks and Their Post-Translational Modifications
Published on: April 21, 2023
Related Concept Videos
Therapeutic Drug Monitoring: Drug Analysis Methods
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...