Related Experiment Video
Updated: Mar 15, 2026

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Utilization of a gum elastic bougie to facilitate single lung intubation
Michael Gottlieb1, Vibhu Sharma2, John Field3
1Department of Emergency Medicine, Rush University Medical Center, 1750 W Harrison St, Suite 108 Kellogg Bldg, Chicago, IL, 60612.
Introduction:
Patients with severe pulmonary hemorrhage due to unilateral trauma or a bleeding cancer often present to the emergency department in acute respiratory distress. Although it is generally recommended to perform single lung intubation, most emergency department providers do not have access to or are not familiar with double-lumen endotracheal tubes, and blind insertion of an endotracheal tube to maximum depth does not ensure that the proper (nonhemorrhagic) lung is ventilated. Therefore, single lung intubation may be significantly delayed in these patients. The purpose of this study was to assess the accuracy of using a gum elastic bougie ("bougie") to facilitate single lung intubation.
Methods:
We conducted a prospective, randomized, blinded pilot study assessing the accuracy of bougie-guided single lung intubation in a fresh human cadaveric model. Two investigators each inserted a bougie under video laryngoscope guidance. After passing the vocal cords, the intubator would be randomized to turn the bougie 90° clockwise (for right mainstem intubation) or 90° counterclockwise (for left mainstem intubation). The bougie was then advanced until resistance was met, and the endotracheal tube was subsequently advanced over the bougie. After intubation, a board-certified pulmonologist investigator who was blinded to the initial lung selection used a fiberoptic bronchoscope to confirm placement by assessing endotracheal tube location with respect to the carina. The primary outcome was the accuracy of correct lung placement.
Results:
Two providers performed a total of 45 placements. There were 22 right mainstem and 23 left mainstem intubations. The overall accuracy was 100% (95% confidence interval, 90.2%-100%) for both right and left mainstem intubations.
Discussion:
In our cadaveric model of mainstem intubation, bougie-guided single lung intubation was highly accurate for both left and right mainstem intubations. Future studies should assess the accuracy of this technique among different providers and bodies, as well as live patients.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Suctioning the Nasopharyngeal Airway
Equipment Required
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...

