Related Experiment Video
Updated: Mar 15, 2026

Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
The Inter-rater Reliability of Echocardiographic Diastolic Function Evaluation Among Emergency Physician Sonographers
Turandot Saul1, Nicholas C Avitabile1, Rachel Berkowitz1
1Division of Emergency Ultrasound, Department of Emergency Medicine, Mount Sinai St. Luke's Hospital, Mount Sinai Roosevelt Hospital, New York, New York.
Study Objectives:
In a patient with dyspnea and suspected CHF, the evaluation of diastolic function involves: tissue Doppler of the mitral annulus and 2) pulsed wave Doppler of the mitral inflow. We aimed to 1) determine the inter-rater reliability for overall diastolic function and 2) evaluate the reliability of the individual Doppler measurements.
Methods:
A convenience sample of adult emergency department patients was prospectively enrolled by 8 EPs who had participated in a 1-hour didactic session. Patients were selected if they had a history of CHF or suspected abnormal diastolic function due to chronic hypertension. Diastolic function was considered to be abnormal if Tissue Doppler of the septal e' was <8 cm/s and if the lateral e' was <10 cm/s. In cases of discordance, the E/e' ratio was calculated with ≤8 considered normal and >8 considered abnormal. A Kappa coefficient. Bland-Altman plot and a fixed effect regression model were used in the analysis.
Results:
Thirty-two patients were enrolled, and 3 (9.4%) were excluded due to technical inadequacy. The inter-rater reliability among sonographers for overall interpretation was very good: κ = 0.86 (95% CL [0.67, 1.0]). Based on the Bland-Altman plot, was no consistent bias between readers. There was no evidence to conclude that the readings differed among sonographers: septal e' (p = 0.77), lateral e' (p = 0.89) and E (p = 0.15).
Conclusion:
EP sonographers obtained similar Doppler measurements for diastolic function evaluation with very good inter-rater reliability for the assessment of overall diastolic function.
More Related Videos
08:09Echocardiographic Assessment of Cardiac Anatomy and Function in Adult Rats
Published on: December 13, 2019
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies