Related Experiment Video
Updated: Aug 1, 2026

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Monitoring of Foot Oxygenation with Near-infrared Spectroscopy in Patients with Critical Limb Ischemia Undergoing
R P E Boezeman1, B P Becx1, D A F van den Heuvel2
1Department of Vascular Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands.
Objective:
Near-infrared spectroscopy (NIRS) non-invasively determines tissue oxygen saturation (Sto2) in muscle tissue. Its application to monitor real time hemodynamic changes during percutaneous transluminal angioplasty (PTA) and Sto2 changes in feet 4 weeks after PTA was evaluated.
Methods:
This study included 14 patients with critical limb ischemia (CLI, six patients Rutherford classification Stage IV, two patients Stage V, and six patients Stage VI). In patients with arterial ulcers, NIRS optodes were placed near the ulcer of the diseased foot (Optode 1), and at the same spot at the contralateral foot (Optode 2). In patients without arterial ulcers, Optode 1 was placed on the dorsum of the diseased foot, and Optode 2 was placed on the dorsum of the contralateral foot. Single Sto2 values, ankle brachial indices, and toe brachial indices were obtained at rest before the start of endovascular revascularization and 4 weeks after treatment. During the endovascular procedure, continuous Sto2 measurements were recorded throughout the intervention. Completion angiograms were used to evaluate the success of intervention.
Results:
Patients underwent treatment of the superficial femoral artery (79%), popliteal artery (21%), and below the knee arteries (43%). In 13 of the 14 patients, completion angiograms showed successful treatment of target lesions. Ankle brachial indices and toe brachial indices significantly increased 4 weeks after treatment (both p < .01). Single Sto2 values of Optode 1 also significantly increased four weeks after treatment (p < .01). In contrast, single Sto2 values of Optode 2 did not (p = .73). During the endovascular procedure, continuous Sto2 measurements of Optode 1 and 2 did not increase (p = .80, and p = .61, respectively).
Conclusions:
NIRS monitoring of foot oxygenation in patients undergoing endovascular revascularization is safe and feasible. NIRS is a promising non-invasive technique to monitor hemodynamic changes in the feet of CLI patients after endovascular treatment using single Sto2 values.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation