Related Experiment Video
Updated: Mar 15, 2026

Fast and Simplified Method for High Through-put Isolation of miRNA from Highly Purified High Density Lipoprotein
Published on: July 27, 2016
Tailor-made approach for selective isolation and elution of low-density lipoproteins by immunoaffinity sorbent on
Ning Gan1, Evgen Multia1, Heli Sirén1
1Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, PO. Box 55, FI-00014, Finland.
Abstract:
Immunoaffinity procedure was developed for isolation of low density lipoprotein (LDL) from biological samples by using silica-derived immunoaffinity sorbent. Sorbent was prepared by immobilization of monoclonal anti-apoB-100 antibody onto macroporous silica particles, using carefully optimized binding chemistry. Binding capacity of the sorbent towards LDL was determined by batch extraction experiments with solutions of isolated LDL in phosphate-buffered saline, and found to be 8 mg LDL/g. The bound LDL fraction was readily released from the sorbent by elution with ammonia at pH 11.2. The total time needed for isolation procedure was less than 1 h, with LDL recoveries being essentially quantitative for samples containing less than 0.3 mg LDL/mL. With higher concentrations, recoveries were less favorable, most probably due to irreversible adsorption caused by LDL aggreggation. However, reusability studies with isolated LDL at concentration 0.2 mg/mL indicate that the developed immunoaffinity material may be used for multiple binding-release cycles, with minor losses in binding capacity. Finally, the sorbent was successfully applied to isolation of LDL from diluted plasma. Apart from its practical implications for LDL isolation, this study provides crucial insights into issues associated with LDL-sorbent interactions, and may be useful in future efforts directed to development of lipoprotein isolation approaches.
More Related Videos
10:39Isolation of High-density Lipoproteins for Non-coding Small RNA Quantification
Published on: November 28, 2016
07:33Lipid Vesicle-mediated Affinity Chromatography using Magnetic Activated Cell Sorting LIMACS: a Novel Method to Analyze Protein-lipid Interaction
Published on: April 26, 2011
Related Concept Videos
Overview Of Cell Separation And Isolation
Affinity Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...