Variability of breathing during wakefulness while using CPAP predicts adherence
Yukio Fujita1, Motoo Yamauchi1, Hiroki Uyama1
1Second Department of Internal Medicine (Department of Respiratory Medicine), Nara Medical University, Kashihara, Japan.
Background And Objective:
The standard therapy for obstructive sleep apnoea (OSA) is continuous positive airway pressure (CPAP) therapy. However, long-term adherence remains at ~50% despite improvements in behavioural and educational interventions. Based on prior work, we explored whether regularity of breathing during wakefulness might be a physiologic predictor of CPAP adherence.
Methods:
Of the 117 consecutive patients who were diagnosed with OSA and prescribed CPAP, 79 CPAP naïve patients were enrolled in this prospective study. During CPAP initiation, respiratory signals were collected using respiratory inductance plethysmography while wearing CPAP during wakefulness in a seated position. Breathing regularity was assessed by the coefficient of variation (CV) for breath-by-breath estimated tidal volume (VT ) and total duration of respiratory cycle (Ttot). In a derivation group (n = 36), we determined the cut-off CV value which predicted poor CPAP adherence at the first month of therapy, and verified the validity of this predetermined cut-off value in the remaining participants (validation group; n = 43).
Results:
In the derivation group, the CV for estimated VT was significantly higher in patients with poor adherence than with good adherence (median (interquartile range): 44.2 (33.4-57.4) vs 26.0 (20.4-33.2), P < 0.001). The CV cut-off value for estimated VT for poor CPAP adherence was 34.0, according to a receiver-operating characteristic (ROC) curve. In the validation group, the CV value for estimated VT >34.0 confirmed to be predicting poor CPAP adherence (sensitivity, 0.78; specificity, 0.83).
Conclusion:
At the initiation of therapy, breathing regularity during wakefulness while wearing CPAP is an objective predictor of short-term CPAP adherence.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes and Capacities I
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...