Surgical Management of Tibial Plateau Fractures With 3.5 mm Simple Plates
Related Experiment Video
Updated: Mar 15, 2026

Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Abolfazl Bagherifard1, Mahmoud Jabalameli1, Hosseinali Hadi1
1Bone and Joint Reconstruction Research Center, Shafa Orthopedic Hospital, Iran University of Medical Sciences, Tehran, IR Iran.
Background:
Tibial plateau fractures can be successfully fixed utilizing 3.5 mm locking plates. However, there are some disadvantages to using these plates.
Objectives:
In the current prospective study, we investigated the outcome of treating different types of tibial plateau fractures with 3.5 mm simple plates which, to our knowledge, has not been evaluated in previous studies.
Materials And Methods:
Between 2011 and 2013, 32 patients aged 40 ± 0.2 years underwent open reduction and internal fixation for tibial plateau fractures with 3.5 mm simple plates. The patients were followed for 16.14 ± 2.1 months. At each patient's final visit, the articular surface depression, medial proximal tibial angle, and slope angle were measured and compared with measurements taken early after the operation. The functional outcomes were measured with the WOMAC and Lysholm knee scores.
Results:
The mean union time was 13 ± 1.2 weeks. The mean knee range of motion was 116.8° ± 3.3°. The mean WOMAC and Lysholm scores were 83.5 ± 1.8 and 76.8 ± 1.6, respectively. On the early postoperative and final X-rays, 87.5% and 84% of patients, respectively, had acceptable reduction. Medial proximal tibial and slope angles did not change significantly by the last visit. No patient was found to have complications related to the type of plate.
Conclusions:
In this case series study, the fixation of different types of tibial plateau fractures with 3.5 mm simple non-locking and non-precontoured plates was associated with acceptable clinical, functional, and radiographic outcomes. Based on the advantages and costs of these plates, the authors recommend using 3.5 mm simple plates for different types of tibial plateau fractures.