Related Experiment Video
Updated: Mar 15, 2026

Fetal Mouse Cardiovascular Imaging Using a High-frequency Ultrasound 30/45MHZ System
Published on: May 5, 2018
Fetal Cardiodynamics by Echocardiography in Insulin Dependent Maternal Diabetes and Its Correlation with Pregnancy
Rashmi Pilania1, Pooja Sikka2, Manoj K Rohit3
1Senior resident, Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences , New Delhi, India . (Was Junior Resident, Department of Obstetrics and Gynaecology, Postgraduate Institute of Medical Education and Research, Chandigarh at time of research).
Introduction:
Maternal diabetes mellitus is associated with an increased risk of fetal and neonatal morbidity and mortality. Usual screening tests have not proved to be good prognostic indicators of fetal distress. Fetal cardiodynamics is potentially a useful screening tool.
Aim:
To determine if cardiodynamics of the fetus differ in pregnancy with diabetes requiring insulin than those without and to determine whether cardiodynamics predict fetal and neonatal outcomes.
Materials And Methods:
This prospective case control study was carried out in 40 pregnant women with diabetes who required insulin for blood sugar control. Twenty uncomplicated pregnant women were taken as controls. Systolic and diastolic cardiac functions along with interventricular septal thickness were assessed at 26-28 weeks and again at 34-36 weeks of gestation in fetuses by echocardiography. Fetal and neonatal adverse outcomes were evaluated in terms of major and minor morbidity.
Results:
Among all parameters, E/A ratio across both mitral and tricuspid valves, myocardial performance index and cardiac output were significantly different in fetuses of diabetic mothers at both gestations. However, pulmonary vein pulsatility index and interventricular septal thickness were similar between the two groups. At 26-28 weeks of gestation myocardial performance index correlated with abnormal biophysical profile whereas cardiac output correlated with minor morbidity. At 34-36 weeks of gestation, cardiac output correlated with abnormal biophysical profile while both MPI and cardiac output correlated with minor morbidity.
Conclusion:
Echocardiographic parameters of fetuses of diabetic women significantly differed from those of uncomplicated non-diabetic women. However, only myocardial performance index and cardiac output correlated with adverse fetal and neonatal outcomes.