Development and preclinical testing of an adaptive algorithm for automated control of inspired oxygen in the preterm
Peter A Dargaville1,2, Omid Sadeghi Fathabadi3, Gemma K Plottier2,4
1Neonatal Respiratory Group, Menzies Institute for Medical Research, University of Tasmania, Hobart, Tasmania, Australia.
Objective:
To assess the performance of a novel algorithm for automated oxygen control using a simulation of oxygenation founded on in vivo data from preterm infants.
Methods:
A proportional-integral-derivative (PID) control algorithm was enhanced by (i) compensation for the non-linear SpO2-PaO2 relationship, (ii) adaptation to the severity of lung dysfunction and (iii) error attenuation within the target range. Algorithm function with and without enhancements was evaluated by iterative linking with a computerised simulation of oxygenation. Data for this simulation (FiO2 and SpO2 at 1 Hz) were sourced from extant recordings from preterm infants (n=16), and converted to a datastream of values for ventilation:perfusion ratio and shunt. Combination of this datastream second by second with the FiO2 values from the algorithm under test produced a sequence of novel SpO2 values, allowing time in the SpO2 target range (91%-95%) and in various degrees of hypoxaemia and hyperoxaemia to be determined. A PID algorithm with 30 s lockout after each FiO2 adjustment, and a proportional-derivative (PD) algorithm were also evaluated.
Results:
Separate addition of each enhancing feature to the PID algorithm showed a benefit, but not with uniformly positive effects. The fully enhanced algorithm was optimal for the combination of targeting the desired SpO2 range and avoiding time in, and episodes of, hypoxaemia and hyperoxaemia. This algorithm performed better than one with a 30 s lockout, and considerably better than PD control.
Conclusions:
An enhanced PID algorithm was very effective for automated oxygen control in a simulation of oxygenation, and deserves clinical evaluation.
More Related Videos
11:49Quantitative and Temporal Control of Oxygen Microenvironment at the Single Islet Level
Published on: November 17, 2013
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Neural Control of Respiration
Respiratory Centers in the Brainstem
Two primary areas comprise the respiratory center: the medullary respiratory center in the medulla oblongata and the pontine respiratory group in the pons. The...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings