Related Experiment Video
Updated: Mar 15, 2026

Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
Effect of transmembrane pressure control on energy efficiency during skim milk concentration by ultrafiltration at 10
S Méthot-Hains1, S Benoit1, C Bouchard2
1STELA Dairy Research Center, Institute of Nutrition and Functional Foods, Department of Food Science, Université Laval, Québec, Canada, G1V 0A6.
Abstract:
The efficiency of the ultrafiltration process during skim milk concentration was studied using both dynamic and constant (465 or 672kPa) transmembrane pressure experiments at refrigerated temperature (10°C) and high temperature (50°C). The pilot-scale module was equipped with a 10-kDa polyethersulfone spiral-wound membrane element with a surface area of 2.04m2. Permeation flux, resistance-in-series model, mineral and protein rejection, and energy consumption were studied as a function of temperature and transmembrane pressure applied. Higher permeation flux values were systematically obtained at 50°C. Also, a significant temperature effect was found for calcium rejection, which was lower at 10°C compared with 50°C. Total hydraulic resistance and reversible fouling resistance were higher at 50°C than at 10°C. No change in protein rejection was observed, depending on the operating mode studied. Permeation flux, which was higher at 50°C, had lower pumping energy consumption compared with ultrafiltration at the colder temperature. Also, the low ultrafiltration temperature required a higher total energy consumption to reach the 3.6× retentate compared with ultrafiltration at 50°C. Overall, our study shows that the operating parameters and temperature can be optimized using an energy efficiency ratio.
More Related Videos
10:53Concentration of Virus Particles from Environmental Water and Wastewater Samples Using Skimmed Milk Flocculation and Ultrafiltration
Published on: March 17, 2023
06:45Author Spotlight: Optimizing Hollow-Fiber Membranes for Continuous Liquid-Liquid Extraction of Medium-Chain Fatty Acids
Published on: August 9, 2024
Related Concept Videos
Osmosis and Osmotic Pressure of Solutions
Capillary Exchange
Fluid Movement Between Compartments
The Significance of Membrane Transport
Transporters facilitate either an active or passive movement of solutes. They can allow a single-molecule transport down its...
Conservation of Energy in Control Volume
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
Physiology of the Genitourinary System II: Tubular Reabsorption and Secretion