Related Experiment Video
Updated: Mar 15, 2026

DNA-affinity-purified Chip DAP-chip Method to Determine Gene Targets for Bacterial Two component Regulatory Systems
Published on: July 21, 2014
Analytical solution and meaning of feasible regions in two-component three-way arrays
Nematollah Omidikia1, Hamid Abdollahi2, Mohsen Kompany-Zareh2
1Institute of Process Engineering, Faculty of Engineering, University of Szeged, Moszkvai krt. 5-7, H-6725 Szeged, Hungary; Department of Chemistry, Institute for Advanced Studies in Basic Sciences, P.O. Box 45195-1159, Zanjan, Iran.
Abstract:
Although many efforts have been directed to the development of approximation methods for determining the extent of feasible regions in two- and three-way data sets; analytical determination (i.e. using only finite-step direct calculation(s) instead of the less exact numerical ones) of feasible regions in three-way arrays has remained unexplored. In this contribution, an analytical solution of trilinear decomposition is introduced which can be considered as a new direct method for the resolution of three-way two-component systems. The proposed analytical calculation method is applied to the full rank three-way data array and arrays with rank overlap (a type of rank deficiency) loadings in a mode. Close inspections of the analytically calculated feasible regions of rank deficient cases help us to make clearer the information gathered from multi-way problems frequently emerged in physics, chemistry, biology, agricultural, environmental and clinical sciences, etc. These examinations can also help to answer, e.g., the following practical question: "Is two-component three-way data with proportional loading in a mode actually a three-way data array?" By the aid of the additional information resulted from the investigated feasible regions of two-component three-way data arrays with proportional profile in a mode, reasons for the inadequacy of the seemingly trilinear data treatment methods published in the literature (e.g., U-PLS/RBL-LD that was used for extraction of quantitative and qualitative information reported by Olivieri et al. (Anal. Chem. 82 (2010) 4510-4519)) could be completely understood.
Related Concept Videos
Normal and Tangetial Components: Problem Solving
Gaussian Elimination: Problem Solving
Vector Algebra: Method of Components
In many applications, the magnitudes and directions of...
Area Computation by the Alternative Coordinate Method
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
Area Between Curves: Problem Solving

