Related Experiment Video
Updated: Mar 15, 2026

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
Decontamination of spent ion-exchangers contaminated with cesium radionuclides using resorcinol-formaldehyde resins
Marina Palamarchuk1, Andrey Egorin1, Eduard Tokar1
1Institute of Chemistry, Far-Eastern Branch, Russian Academy of Sciences, 159, prosp. 100-letiya Vladivostoka, Vladivostok 690022, Russia.
Abstract:
The origin of the emergence of radioactive contamination not removable in the process of acid-base regeneration of ion-exchange resins used in treatment of technological media and liquid radioactive waste streams has been determined. It has been shown that a majority of cesium radionuclides not removable by regeneration are bound to inorganic deposits on the surface and inside the ion-exchange resin beads. The nature of the above inorganic inclusions has been investigated by means of the methods of electron microscopy, IR spectrometry and X-ray diffraction. The method of decontamination of spent ion-exchange resins and zeolites contaminated with cesium radionuclides employing selective resorcinol-formaldehyde resins has been suggested. Good prospects of such an approach in deep decontamination of spent ion exchangers have been demonstrated.