Testing for Multivariate Normality in Mass Spectrometry Imaging Data: A Robust Statistical Approach for Clustering
Alex Dexter1, Alan M Race1, Iain B Styles
1National Physical Laboratory , Teddington, Middlesex TW11 0LW, United Kingdom.
Abstract:
Spatial clustering is a powerful tool in mass spectrometry imaging (MSI) and has been demonstrated to be capable of differentiating tumor types, visualizing intratumor heterogeneity, and segmenting anatomical structures. Several clustering methods have been applied to mass spectrometry imaging data, but a principled comparison and evaluation of different clustering techniques presents a significant challenge. We propose that testing whether the data has a multivariate normal distribution within clusters can be used to evaluate the performance when using algorithms that assume normality in the data, such as k-means clustering. In cases where clustering has been performed using the cosine distance, conversion of the data to polar coordinates prior to normality testing should be performed to ensure normality is tested in the correct coordinate system. In addition to these evaluations of internal consistency, we demonstrate that the multivariate normal distribution can then be used as a basis for statistical modeling of MSI data. This allows the generation of synthetic MSI data sets with known ground truth, providing a means of external clustering evaluation. To demonstrate this, reference data from seven anatomical regions of an MSI image of a coronal section of mouse brain were modeled. From this, a set of synthetic data based on this model was generated. Results of r2 fitting of the chi-squared quantile-quantile plots on the seven anatomical regions confirmed that the data acquired from each spatial region was found to be closer to normally distributed in polar space than in Euclidean. Finally, principal component analysis was applied to a single data set that included synthetic and real data. No significant differences were found between the two data types, indicating the suitability of these methods for generating realistic synthetic data.
More Related Videos
08:04A New Approach for the Comparative Analysis of Multiprotein Complexes Based on 15N Metabolic Labeling and Quantitative Mass Spectrometry
Published on: March 13, 2014
08:27Large-Scale Multi-Omics Genome-Wide Association Studies Mo-GWAS: Guidelines for Sample Preparation and Normalization
Published on: July 27, 2021
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Overview
Mass Spectrometers
MALDI-TOF Mass Spectrometry
Tandem Mass Spectrometry
Mass Spectrum: Interpretation