Related Experiment Video
Updated: Mar 14, 2026

Author Spotlight: Enhancing Success of Ultrasound-Guided Neuraxial Anesthesia in Cases with Difficult Anatomy
Published on: January 31, 2025
Comparing the Hemodynamic Effects of Spinal Anesthesia in Preeclamptic and Healthy Parturients During Cesarean
Mahshid Nikooseresht1, Mohamad Ali Seif Rabiei2, Pooran Hajian1
1Department of Anesthesiology, School of Medicine, Hamedan University of Medical Sciences, Hamedan, Iran.
Background:
Despite controversies about the safest anesthetic technique for cesarean delivery in severely preeclamptic women, there is evidence that supports the use of spinal anesthesia in this group of patients.
Objectives:
This prospective randomized clinical trial was designed to determine the hemodynamic effects of low-dose spinal bupivacaine and the incidence of spinal anesthesia-associated hypotension in severely preeclamptic and healthy parturients undergoing cesarean sections.
Patients And Methods:
Spinal anesthesia was performed with 10 mg (= 2 mL) hyperbaric 0.5% bupivacaine plus 2.5 µg sufentanil in two groups of patients after they received 500 mL of IV lactated Ringer's solution. Heart rate and blood pressure were recorded before spinal anesthesia and at two minutes intervals for 15 minutes after the block, and then every five minutes until the end of the surgery. Hypotension was defined as more than 25% of decline in the mean arterial blood pressure compared to the baseline in both groups (or systolic blood pressure < 100 mmHg in healthy parturients) and was treated with 5 mg IV ephedrine. The total amounts of intravenous administered fluid and the total doses of ephedrine were recorded for each patient as well.
Results:
The incidence rate of hypotension among the preeclamptic patients was lower than that of the healthy parturients, despite the former group receiving smaller volumes of intravenous fluids (P < 0.05). The total doses of IV ephedrine for treating hypotension were significantly lower among the preeclamptic patients (3.2 mg in preeclamptic patients versus 7.6 mg in normotensive patients) (P = 0.02). The one-minute Apgar score was significantly lower for the preeclamptic parturients (8.4 ± 0.7 versus 7.2 ± 1.5) (P = 0.001), but there was no significant difference in the five-minute Apgar scores between the two groups.
Conclusions:
Our results confirm that low-dose bupivacaine spinal anesthesia is associated with a lower risk of hypotension than previously believed, and it can therefore be safely used in severe preeclamptic women undergoing cesarean delivery.
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Clinical Application as Spinal Anesthesia
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Aneurysm IV: Nursing Management
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...

