Related Experiment Video
Updated: Mar 14, 2026

Imaging In-Stent Restenosis: An Inexpensive, Reliable, and Rapid Preclinical Model
Published on: September 14, 2009
Effects of Methotrexate in a Rabbit Model of In-Stent Neoatherosclerosis: An Optical Coherence Tomography Study
Ruoxi Zhang1, Shuyuan Chen1, Hui Zhang1
1Department of Cardiology, Key Laboratories of Education Ministry for Myocardial Ischemia Mechanism and Treatment, 2nd Affiliated Hospital of Harbin Medical University, Harbin 150086, China.
Abstract:
This study used optical coherence tomography (OCT) to investigate the effects of systemic methotrexate, in combination with a drug-eluting stent, on in-stent neoatherosclerosis in a rabbit model. Sirolimus-eluting stents were surgically implanted in the right common carotid arteries of 200 male New Zealand White rabbits; the animals received a high-fat diet, beginning one week before stent implantation. Each animal was randomly assigned to 1 of 4 groups, receiving intravenous injections of either methotrexate (0.4 mg/kg) or placebo weekly for 4 or 12 weeks. Stented arterial segments were harvested after stenting for 4 or 12 weeks, and processed for OCT and histological analysis. Prior to harvesting the arterial segments, blood was collected for the determinations of cytokine levels. Compared with the control animals, the methotrexate-treated animals showed lower rates of lipid-rich intima and per-strut low-signal intensity layers, smaller neointimal areas, and reduced neointimal thickness; larger fibrous cap thicknesses and smaller lumen areas were also seen in the animals receiving methotrexate. The levels of serum interleukin, adhesion molecules, and nuclear factor-κB p65 decreased and IL-10 level increased in the methotrexate-treated animals. Targeting the pro-inflammatory pathways may be an effective way to prevent restenosis without the long-term risk of late thrombosis.