High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Simultaneous Orthogonal Drug Detection Using Fully Integrated Gas Chromatography with Fourier Transform Infrared
Adam Lanzarotta1, Travis Falconer1, Heather McCauley1
1FDA Forensic Chemistry Center, Cincinnati, Ohio, USA.
Abstract:
Analytes that co-elute and yield nearly identical electron ionization (EI) mass spectra, as well as analytes that yield non-specific EI fragmentation patterns, have been identified using fully integrated gas chromatography with direct deposit Fourier transform infrared detection and mass spectrometric detection (GC/FT-IR/MS). While the IR detector proved to be more selective for identifying analytes such as synthetic cannabinoids and weight loss drugs, it was limited by a relatively high detection limit of 8.4 parts per million (ppm) for non-targeted identification of sibutramine based on a single injection but was reduced to 840 parts per billion (ppb) for targeted identification of sibutramine by redepositing ten injections along the same track. The MS detector was less selective for identifying these analytes but yielded non-targeted and targeted detection limits of approximately 84 ppb and 8.4 ppb, respectively, which corresponded to a 100-fold advantage compared to the IR detector. Overall, the results of this study demonstrate that the advantages of each detector compensate for the limitations of the other, which allows a wider range of analytes and concentrations to be examined using a fully integrated GC/FT-IR/MS instrument compared to what can be examined using GC/IR or GC/MS independently. Not only does this approach reduce consumption of laboratory resources and time, it provides IR and MS information on the same sample, which is important for forensic analyses that require data from two or more orthogonal techniques to make an identification.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Tandem Mass Spectrometry
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...