The Mayak Worker Dosimetry System (MWDS-2013): How to Reduce Hyper-Realisations to Realisations.
1Global Dosimetry, Didcot, Oxon, UK.
The new Medical Internal and External Dosimetry System (MWDS-2013) accounts for uncertainties in absorbed dose calculations by using multiple realizations. This approach better reflects parameter uncertainties for epidemiological studies.
Area of Science:
- Medical Physics
- Radiation Dosimetry
- Epidemiology
Background:
- Previous dosimetry databases (MWDS-2008, DOSES-2005) used single realizations for organ dose calculations.
- These databases did not explicitly address uncertainties in model parameters or differentiate between shared and unshared parameters.
Purpose of the Study:
- To introduce and evaluate methods for converting multiple hyper-realizations of organ doses into tractable realisations for epidemiological analysis.
- To account for uncertainties in model parameters, including shared and unshared types, in absorbed dose calculations.
Main Methods:
- A multiple-realisation approach generating 1000 realisations to capture parameter uncertainty.
- Bayesian calculation of organ doses resulting in hyper-doses (distributions) rather than single values.
- Development and discussion of methods to convert hyper-realisations to realisations and derive single point estimates for epidemiological analysis.
Main Results:
- The MWDS-2013 explicitly handles uncertainties in model parameters.
- It differentiates between shared and unshared parameters, preserving information on their effects on internal and external doses.
- Multiple hyper-realisations were generated, requiring conversion for epidemiological tractability.
Conclusions:
- The chosen method for converting hyper-realisations to realisations facilitates preliminary epidemiological analyses.
- The MWDS-2013 provides a more robust estimation of absorbed doses by incorporating parameter uncertainties.
- Single point dose estimates were also derived to support epidemiological investigations.
More Related Videos
08:53Preparation of Single-cohort Colonies and Hormone Treatment of Worker Honeybees to Analyze Physiology Associated with Role and/or Endocrine System
Published on: September 6, 2016
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Adaptations that Reduce Water Loss
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Methods of reducing fever
Pharmacological Methods of Reducing Fever:
Role of Reduced Coenzymes NADH and FADH₂
Redox Titration: Other Oxidizing and Reducing Agents
Reduced Mass Coordinates: Isolated Two-body Problem