The chromatography of poly(phenylene ether) on a porous graphitic carbon sorbent
Stephan Moyses1, Anton Ginzburg2
1SABIC, 1600 Industrial Blvd., Sugar Land, TX 77478, USA.
Abstract:
A Porous Graphitic Carbon (PGC) column was evaluated for the analysis of poly(phenylene ether) (PPE). This column appears particularly well-suited for the separation of this polymer. Conditions for the elution of PPE either in adsorption mode with chloroform or size exclusion with 1,2,4-trichlorobenzene (TCB) as eluent were established. Elution of homologous species is obtained in chloroform that follows Martin's rule. A separation based on a gradient consisting of a sequence of non-solvent (acetonitrile), solvent/adsorli (chloroform) provided the highest peak capacity. In TCB, it is possible to obtain rapid size-based separation: with a flow rate of 0.7ml/min, the run time is less than two minutes for a series of polystyrene standards. The PGC column performs remarkably well in this mode and may be a viable solution when a short analysis time is critical such as in a combinatorial laboratory or in a two-dimensional chromatograph. In addition to its value as a sorbent for polymer separation, this column also deserves the attention of the materials engineer. Indeed, the PGC sorbent can be used as a model to probe the interaction between polymers and graphitic fillers such as carbon nanotubes or graphite nanosheets.
More Related Videos
10:27Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Ion-Exchange Chromatography
Analyte Adsorption and Distribution
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...