Related Experiment Video
Updated: Mar 14, 2026

Isolation and Characterization Of Chimeric Human Fc-expressing Proteins Using Protein A Membrane Adsorbers And A Streamlined Workflow
Published on: January 8, 2014
Choosing the right protein A affinity chromatography media can remove aggregates efficiently
Tomokazu Yada1, Koichi Nonaka1, Masayuki Yabuta1
1Biologics Research Laboratories, R&D division, Daiichi Sankyo Co., Ltd, Oura-gun, Japan.
This study proposes a new method for selecting Protein A chromatography (PAC) media based on monoclonal antibody (mAb) aggregate removal. Protocol B, using arginine wash, demonstrated superior aggregate removal and monomer yield compared to Protocol A.
Area of Science:
- Biochemistry
- Chemical Engineering
- Biotechnology
Background:
- Protein A chromatography (PAC) is a standard capture method for monoclonal antibody (mAb) purification.
- Current selection criteria for PAC often focus on dynamic binding capacity, potentially overlooking aggregate removal efficiency.
- Efficient aggregate removal during initial capture can simplify downstream polishing steps.
Purpose of the Study:
- To develop and validate a method for selecting Protein A chromatography media based on monoclonal antibody (mAb) aggregate removal.
- To evaluate the elution behavior of mAb aggregates and monomers on different PAC columns.
- To compare the efficacy of two stepwise elution protocols for aggregate removal.
Main Methods:
- Linear pH gradient elution experiments were performed using two distinct mAbs on various PAC columns.
- The elution profiles of both mAb aggregates and monomers were quantified.
- Two stepwise elution protocols (A: low pH elution; B: 1.0 M arginine wash followed by elution) were tested for aggregate removal.
Main Results:
- Different mAbs exhibited varied aggregate elution behaviors; one showed stronger retention of aggregates than monomers, while another eluted aggregates in both weakly and strongly retained fractions.
- Protocol A resulted in no detectable aggregate peaks during the wash stage.
- Protocol B, incorporating a 1.0 M arginine wash, effectively monitored aggregate peaks and demonstrated higher aggregate removal and monomer yield compared to Protocol A and other PAC columns.
Conclusions:
- A novel method for selecting PAC media based on aggregate removal efficiency is presented.
- The proposed method, utilizing specific elution conditions, aids in optimizing PAC selection for improved mAb purification.
- Protocol B, with an arginine wash, proved more effective for aggregate removal and maintaining monomer yield, highlighting its utility in PAC media selection.
More Related Videos
07:53Activated Cross-linked Agarose for the Rapid Development of Affinity Chromatography Resins - Antibody Capture as a Case Study
Published on: August 16, 2019
10:08An Economical and Versatile High-Throughput Protein Purification System Using a Multi-Column Plate Adapter
Published on: May 21, 2021
Related Concept Videos
Affinity Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...